The Microcircuit,linear, cataloged under National Stock Number 5962-01-094-9598, is classified within Federal Supply Class 5962 (Microcircuits, Electronic) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Drs Network & Imaging Systems, Llc. Government technical data includes 11 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5962-01-094-9598 |
| Primary Part Number | 232/50-0071 |
| Item Name | Microcircuit,linear |
| FSC / FSG | 5962 / 59 — Microcircuits, Electronic |
| Manufacturer | Drs Network & Imaging Systems, Llc |
| Status | ACTIVE |
| Input Circuit Pattern | QUAD 2 INPUT |
| Inclosure Material | SILICON |
| Terminal Surface Treatment | SOLDER |
| Design Function and Quantity | 4 AMPLIFIER, OPERATIONAL, INSTRUMENTATION |
| Body Width | 0.220 INCHES MINIMUM AND 0.310 INCHES MAXIMUM IN |
| Body Height | 0.185 INCHES MINIMUM AND 0.192 INCHES MAXIMUM IN |
| Features Provided | BURN IN, MIL-STD-883, CLASS A AND LOW NOISE |
| Inclosure Configuration | DUAL-IN-LINE |
| Body Length | 0.796 INCHES NOMINAL IN |
| Operating Temp Range | -55.0 TO 125.0 CELSIUS DEGC |
| Maximum Power Dissipation Rating | 800.0 MILLIWATTS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL Q — CCL Item — Commerce Control List |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 232/50-0071 PRIMARY | Drs Network & Imaging Systems, Llc (USA) |
| OP-09-883-AY | Analog Devices, Inc. Div Santa Clara Site (USA) |
| Reference | Meaning |
|---|---|
| OP-09AY/883 | 5/1 Secondary reference Analog Devices, Inc. Div Santa Clara Site |
| 232/50-0071 | 5/9 Secondary reference General Dynamics Land Systems Inc. |
| 12280071 | 5/9 Secondary reference U S Army Tank Automotive Command Amsta-Im-Mm |
NSN 5962-01-094-9598 is a Microcircuit,linear, manufactured by Drs Network & Imaging Systems, Llc, classified under FSC 5962, Microcircuits, Electronic. Status: active.
NSN 5962-01-094-9598 has 2 manufacturer part numbers on file: 232/50-0071 (Drs Network & Imaging Systems, Llc), OP-09-883-AY (Analog Devices, Inc. Div Santa Clara Site).
2 possible matches (shared part number, not a government interchangeability claim): 5962-01-256-3180, 5962-01-318-0259. Verify interchangeability with system specifications before substitution.
Key specifications for 232/50-0071: Input Circuit Pattern: QUAD 2 INPUT; Inclosure Material: SILICON; Terminal Surface Treatment: SOLDER; Design Function and Quantity: 4 AMPLIFIER, OPERATIONAL, INSTRUMENTATION. 11 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
NSN 5962-01-094-9598 has DEMIL Code Q. Demilitarization may be required before disposal or transfer to non-military entities.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.