The Semiconductor Device,diode, cataloged under National Stock Number 5961-01-697-9437, is classified within Federal Supply Class 5961 (Semiconductor Devices and Associated Hardware) of the Electrical and Electronic Equipment Components group. Government technical data includes 11 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5961-01-697-9437 |
| Item Name | Semiconductor Device,diode |
| FSC / FSG | 5961 / 59 — Semiconductor Devices and Associated Hardware |
| Status | ACTIVE |
| Voltage Rating in Volts Per Characteristic | 1.34 NOMINAL FORWARD VOLTAGE, AVERAGE |
| Maximum Operating Temp Per Measurement Point | 55.0 CELSIUS JUNCTION AND 175.0 CELSIUS JUNCTION DEGC |
| Mounting Method | UNTHREADED HOLE(S) |
| Features Provided | ROHS DIRECTIVE COMPLIANCE |
| Capacitance Rating in Picofarads | 50.0 NOMINAL |
| Current Rating Per Characteristic | 30.0 AMPERES NOMINAL FORWARD CURRENT, AVERAGE |
| Voltage Tolerance in Percent | +25.0 TO 150.0 |
| Terminal Type and Quantity | 3 PIN |
| Terminal Circle Diameter | 0.99 MILLIMETERS MINIMUM AND 1.40 MILLIMETERS MAXIMUM MM |
| Electrode Internally-Electrically Connected to Case | CATHODE |
| Power Rating Per Characteristic | 160.0 WATTS NOMINAL TOTAL POWER DISSIPATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| DPG60C200HB | 3/9 Design control — primary reference Ixys, Llc |
NSN 5961-01-697-9437 is a Semiconductor Device,diode, classified under FSC 5961, Semiconductor Devices and Associated Hardware. Status: active.
Key specifications for 5961-01-697-9437: Overall Height: 4.70 MILLIMETERS MINIMUM AND 5.30 MILLIMETERS MAXIMUM MM; Voltage Rating in Volts Per Characteristic: 1.34 NOMINAL FORWARD VOLTAGE, AVERAGE; Maximum Operating Temp Per Measurement Point: 55.0 CELSIUS JUNCTION AND 175.0 CELSIUS JUNCTION DEGC; Mounting Method: UNTHREADED HOLE(S). 11 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.