The Semiconductor Device,diode, cataloged under National Stock Number 5961-01-610-9608, is classified within Federal Supply Class 5961 (Semiconductor Devices and Associated Hardware) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Diodes Inc. Government technical data includes 8 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5961-01-610-9608 |
| Primary Part Number | SMBJ100A-13-F |
| Item Name | Semiconductor Device,diode |
| FSC / FSG | 5961 / 59 — Semiconductor Devices and Associated Hardware |
| Manufacturer | Diodes Inc |
| Status | ACTIVE |
| Voltage Rating in Volts Per Characteristic | 3.5 MINIMUM FORWARD VOLTAGE, AVERAGE AND 5.0 MAXIMUM FORWARD VOLTAGE, AVERAGE |
| Maximum Operating Temp Per Measurement Point | 150.0 CELSIUS AMBIENT AIR DEGC |
| Mounting Facility Quantity | 2 |
| Mounting Method | TERMINAL |
| Current Rating Per Characteristic | 100.0 AMPERES NOMINAL PEAK FORWARD SURGE CURRENT |
| Material | PLASTIC ENCLOSURE |
| Terminal Type and Quantity | 2 BONDING PAD |
| Power Rating Per Characteristic | 600.0 WATTS NOMINAL PEAK PULSE OUTPUT POWER |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| SMBJ100A-13-F PRIMARY | Diodes Inc (USA) |
NSN 5961-01-610-9608 is a Semiconductor Device,diode, manufactured by Diodes Inc, classified under FSC 5961, Semiconductor Devices and Associated Hardware. Status: active.
NSN 5961-01-610-9608 has 1 manufacturer part number on file: SMBJ100A-13-F (Diodes Inc).
Key specifications for SMBJ100A-13-F: Overall Height: 2.00 MILLIMETERS MINIMUM AND 2.62 MILLIMETERS MAXIMUM MM; Voltage Rating in Volts Per Characteristic: 3.5 MINIMUM FORWARD VOLTAGE, AVERAGE AND 5.0 MAXIMUM FORWARD VOLTAGE, AVERAGE; Maximum Operating Temp Per Measurement Point: 150.0 CELSIUS AMBIENT AIR DEGC; Mounting Facility Quantity: 2. 8 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.