PartsTable TECHNICAL DATA SHEET
NSN 5950-01-407-7419Government record, cited

Reactor5950-01-407-7419

NSN 5950-01-407-7419 · NIIN 014077419
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-407-7419 · 5950014077419 · NIIN 014077419 · 01-407-7419 · FSC 5950 Coils and Transformers · ECL2472 · 690543
Nearby stock numbers  ·
Features
  • Reactor — FSC 5950
  • Inclosure Type: FULLY INCLOSED
  • Overall Diameter: 1.197 INCHES MAXIMUM IN
  • Mounting Method: TERMINAL SINGLE GROUP
  • Inductance Rating: 111.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
  • Specification/standard Data: 80249-690543 MANUFACTURERS SPECIFICATION CONTROL
  • Maximum Operating Temp: 130.0 CELSIUS DEGC
  • Winding Operating Current: 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
Identification
  • NSN: 5950-01-407-7419
  • NIIN: 014077419
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Reactor, cataloged under National Stock Number 5950-01-407-7419, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-407-7419
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Inclosure TypeFULLY INCLOSED
Overall Diameter1.197 INCHES MAXIMUM IN
Mounting MethodTERMINAL SINGLE GROUP
Inductance Rating111.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING
Specification/standard Data80249-690543 MANUFACTURERS SPECIFICATION CONTROL
Maximum Operating Temp130.0 CELSIUS DEGC
Winding Operating Current5.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
Rating MethodELECTRICAL SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms0.0696 SINGLE COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT
Frequency Rating2.0 MEGAHERTZ NOMINAL SINGLE COMPONENT
Terminal Type and Quantity2 TURRET
Inductance TypeFIXED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
ECL2472 3/9 Design control — primary reference
U.S. Government activity
690543 7/2 Vendor item drawing reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5950-01-407-7419?

NSN 5950-01-407-7419 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-407-7419?

Key specifications for 5950-01-407-7419: Inclosure Type: FULLY INCLOSED; Overall Diameter: 1.197 INCHES MAXIMUM IN; Mounting Method: TERMINAL SINGLE GROUP; Inductance Rating: 111.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING. 14 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-407-7419 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com