PartsTable TECHNICAL DATA SHEET
NSN 5950-01-394-7230Government record, cited

Transformer, Power5950-01-394-7230

NSN 5950-01-394-7230 · NIIN 013947230
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-394-7230 · 5950013947230 · NIIN 013947230 · 01-394-7230 · FSC 5950 Coils and Transformers · MIL-T-27/66 · MIL-PRF-27/66 · M27/66-16
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Body Outside Diameter: 2.844 INCHES MINIMUM AND 2.906 INCHES MAXIMUM IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Maximum Transformer Power Rating: 250.0 VOLT-AMPERE SINGLE COMPONENT
  • Winding Function and Quantity: 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Identification
  • NSN: 5950-01-394-7230
  • NIIN: 013947230
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-394-7230, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-394-7230
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Body Outside Diameter2.844 INCHES MINIMUM AND 2.906 INCHES MAXIMUM IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Maximum Transformer Power Rating250.0 VOLT-AMPERE SINGLE COMPONENT
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Distance Between Mounting Facility Centers2.250 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Specification/standard Data81349-MIL-T-27/66 GOVERNMENT SPECIFICATION
Maximum Operating Temp130.0 CELSIUS DEGC
Body Length1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM IN
Winding Operating Current2.50 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Test Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Winding Operating Voltage100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage15.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity6 FEED THRU
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-T-27/66 5/9 Secondary reference
U.S. Government activity
MIL-PRF-27/66 4/1 Identification reference
U.S. Government activity
M27/66-16 2/2 Government specification standardization
U.S. Government activity

Frequently Asked Questions

What is NSN 5950-01-394-7230?

NSN 5950-01-394-7230 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-394-7230?

Key specifications for 5950-01-394-7230: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Body Outside Diameter: 2.844 INCHES MINIMUM AND 2.906 INCHES MAXIMUM IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-394-7230 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com