PartsTable TECHNICAL DATA SHEET
NSN 5950-01-381-4137Government record, cited

Transformer, Power5950-01-381-4137

NSN 5950-01-381-4137 · NIIN 013814137 · Part number 1342AS717
Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 30003
Government record, cited
NSN 5950-01-381-4137 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-381-4137. Manufacturer of record part number: 1342AS717.
Also searched as  5950-01-381-4137 · 5950013814137 · NIIN 013814137 · 01-381-4137 · FSC 5950 Coils and Transformers · CAGE 30003 · 1342AS717
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: DELTA-WYE
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO SIX PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Body Width: 4.250 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-381-4137
  • NIIN: 013814137
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 1342AS717
  • Manufacturer: Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-381-4137, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier. Government technical data includes 26 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-381-4137
Primary Part Number1342AS717
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerNaval Air Systems Command Managed Original Design Activity Not Material/parts Supplier
StatusACTIVE
Transformer Winding Connection TypeDELTA-WYE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO SIX PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width4.250 INCHES MAXIMUM IN
Body Height3.400 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Maximum Operating Temp155.0 CELSIUS DEGC
Body Length5.000 INCHES MAXIMUM IN
Winding Operating Current118.8 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Current348.0 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current602.4 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.557 INCHES MINIMUM AND 3.567 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage12.60 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage25.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage25.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity1 TERMINAL BLOCK W/SCREWS
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Hazardous Locations/environmental ProtectionSALT SPRAY RESISTANT
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
1342AS717 Vertex Modernization and Sustainment Llc (USA)
1342AS717 PRIMARY Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier (USA)
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-381-4137?

NSN 5950-01-381-4137 is a Transformer,power, manufactured by Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-381-4137?

NSN 5950-01-381-4137 has 2 manufacturer part numbers on file: 1342AS717 (Vertex Modernization and Sustainment Llc), 1342AS717 (Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier).

What are the specifications of 1342AS717?

Key specifications for 1342AS717: Transformer Winding Connection Type: DELTA-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.995 INCHES MINIMUM AND 2.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-381-4137 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com