PartsTable TECHNICAL DATA SHEET
NSN 5950-01-368-8132Government record, cited

Transformer, Power5950-01-368-8132

NSN 5950-01-368-8132 · NIIN 013688132
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-368-8132 · 5950013688132 · NIIN 013688132 · 01-368-8132 · FSC 5950 Coils and Transformers · MIL-PRF-27/316 · M27/316-04 · MIL-T-27/316
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN
  • Winding Power Rating: 30.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) ALL GROUPINGS
  • Body Width: 2.130 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-368-8132
  • NIIN: 013688132
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-368-8132, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-368-8132
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length2.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN
Winding Power Rating30.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) ALL GROUPINGS
Body Width2.130 INCHES NOMINAL IN
Body Height3.500 INCHES NOMINAL IN
Maximum Transformer Power Rating30.0 VOLT-AMPERE SINGLE COMPONENT
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.164 INCHES ALL GROUPINGS IN
Specification/standard Data81349-MIL-T-27/320 GOVERNMENT SPECIFICATION
Maximum Operating Temp130.0 CELSIUS DEGC
Body Length2.690 INCHES NOMINAL IN
Winding Operating Current3.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.500 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN
Test Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Winding Operating Voltage10.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity5 WIRE HOOK
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) ALL GROUPINGS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5950-01-394-3636 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-PRF-27/316 4/1 Identification reference
U.S. Government activity
M27/316-04 2/2 Government specification standardization
U.S. Government activity
MIL-T-27/316 5/9 Secondary reference
U.S. Government activity
Related Parts
5950-01-394-3636POSSIBLE MATCH
TRANSFORMER,POWER

Frequently Asked Questions

What is NSN 5950-01-368-8132?

NSN 5950-01-368-8132 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-368-8132?

1 possible match (shared part number, not a government interchangeability claim): 5950-01-394-3636. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-368-8132?

Key specifications for 5950-01-368-8132: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.000 INCHES NOMINAL ALL MOUNTING FACILITIES ALL CENTER GROUPINGS IN; Winding Power Rating: 30.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-368-8132 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com