The Reactor-Transformer, cataloged under National Stock Number 5950-01-361-4341, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Hisonic, Llc. Government technical data includes 28 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-361-4341 |
| Primary Part Number | 27-0050-10 |
| Item Name | Reactor-Transformer |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Hisonic, Llc |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Turn Quantity | 50 THIRD COMPONENT SINGLE WINDING |
| Mounting Method | THREADED HOLE(S) SINGLE GROUP |
| Body Width | 2.000 INCHES NOMINAL IN |
| Winding Conductor Size | 0.00795 INCHES AMERICAN WIRE GAGE THIRD COMPONENT SINGLE WINDING IN |
| Winding Function and Quantity | 1 PRIMARY AND 3 SECONDARY FIRST COMPONENT |
| Winding Function and Quantity | 1 PRIMARY SECOND COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD CONNECTED TO SECONDARY TERMINAL FIRST COMPONENT |
| Winding Shielding Method | INTERNALLY SHIELDED AND BROUGHT OUT TO PRIMARY TERMINAL SECOND COMPONENT |
| Features Provided | TINNED WIRE LEADS |
| Nominal Thread Size | 0.112 INCHES SINGLE GROUP IN |
| Maximum Operating Temp | 55.0 CELSIUS DEGC |
| Body Length | 3.400 INCHES NOMINAL IN |
| Winding Operating Current | 16.0 AMPERES AC NOMINAL SECOND COMPONENT SINGLE PRIMARY |
| Rating Method | ELECTRICAL AND WINDING TURNS THIRD COMPONENT SINGLE WINDING |
| DC Resistance Rating in Ohms | 0.15 THIRD COMPONENT SINGLE WINDING |
| DC Resistance Rating in Ohms | 0.150 SINGLE REGISTER SINGLE TIER FIGURE |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 10.0 KILOHERTZ NOMINAL THIRD COMPONENT |
| Frequency Rating | 100.0 KILOHERTZ NOMINAL FIRST COMPONENT |
| Frequency Rating | 100.0 KILOHERTZ NOMINAL SECOND COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 10.00 AC VOLTS NOMINAL SECOND COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 7.70 AC VOLTS NOMINAL FIRST COMPONENT SINGLE PRIMARY |
| Terminal Type and Quantity | 18 WIRE LEAD |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 27-0050-10 | Hisonic, Llc (USA) |
| 27-0055-01 | Hisonic, Llc (USA) |
| Reference | Meaning |
|---|---|
| 217-0090-010 | 5/9 Secondary reference Hisonic, Llc |
| 217-0090-010 | 3/2 Design control — primary reference U.S. Government activity |
| 217-0090-010 | 5/9 Secondary reference Abel Image Research Inc |
| 27-005-10 | 5/9 Secondary reference Hisonic, Llc |
NSN 5950-01-361-4341 is a Reactor-Transformer, manufactured by Hisonic, Llc, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-01-361-4341 has 2 manufacturer part numbers on file: 27-0050-10 (Hisonic, Llc), 27-0055-01 (Hisonic, Llc).
2 possible matches (shared part number, not a government interchangeability claim): 6625-01-515-6453, 4730-01-594-9487. Verify interchangeability with system specifications before substitution.
Key specifications for 27-0050-10: Overall Height: 1.400 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.