PartsTable TECHNICAL DATA SHEET
NSN 5950-01-359-4135Government record, cited

Reactor5950-01-359-4135

NSN 5950-01-359-4135 · NIIN 013594135 · Part number 1850-0001-01
Cxr Larus Corporation Div Cxr Telcom · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 42161
Government record, cited
NSN 5950-01-359-4135 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-359-4135. Manufacturer of record part number: 1850-0001-01.
Also searched as  5950-01-359-4135 · 5950013594135 · NIIN 013594135 · 01-359-4135 · FSC 5950 Coils and Transformers · CAGE 42161 · 1850-0001-01 · ZT3143A
Nearby stock numbers  ·
Features
  • Reactor — FSC 5950
  • Mounting Facility Quantity: 1 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Overall Diameter: 1.670 INCHES MAXIMUM IN
  • Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP
  • Inductance Rating: 2.70 HENRY MINIMUM AND 3.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING
  • Mounting Hole Diameter: 0.140 INCHES NOMINAL SINGLE GROUP IN
  • Features Provided: TINNED WIRE LEADS
Identification
  • NSN: 5950-01-359-4135
  • NIIN: 013594135
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 1850-0001-01
  • Manufacturer: Cxr Larus Corporation Div Cxr Telcom
General Description

The Reactor, cataloged under National Stock Number 5950-01-359-4135, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Cxr Larus Corporation Div Cxr Telcom. Government technical data includes 15 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-359-4135
Primary Part Number1850-0001-01
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerCxr Larus Corporation Div Cxr Telcom
StatusACTIVE
Mounting Facility Quantity1 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Overall Diameter1.670 INCHES MAXIMUM IN
Mounting MethodUNTHREADED HOLE(S) SINGLE GROUP
Inductance Rating2.70 HENRY MINIMUM AND 3.00 HENRY MAXIMUM SINGLE COMPONENT SINGLE WINDING
Mounting Hole Diameter0.140 INCHES NOMINAL SINGLE GROUP IN
Features ProvidedTINNED WIRE LEADS
Maximum Operating Temp105.0 CELSIUS DEGC
Rating MethodELECTRICAL SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms430.000 SINGLE COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT
Frequency Rating1.0 KILOHERTZ MINIMUM AND 4.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
Terminal Type and Quantity2 WIRE LEAD
Inductance TypeFIXED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
ZT3143A Zambre Co Inc (USA)
1850-0001-01 PRIMARY Cxr Larus Corporation Div Cxr Telcom (USA)
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-359-4135?

NSN 5950-01-359-4135 is a Reactor, manufactured by Cxr Larus Corporation Div Cxr Telcom, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-359-4135?

NSN 5950-01-359-4135 has 2 manufacturer part numbers on file: ZT3143A (Zambre Co Inc), 1850-0001-01 (Cxr Larus Corporation Div Cxr Telcom).

What are the specifications of 1850-0001-01?

Key specifications for 1850-0001-01: Mounting Facility Quantity: 1 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Overall Diameter: 1.670 INCHES MAXIMUM IN; Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP. 15 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-359-4135 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com