Features
  • Transformer,power — FSC 5950
  • Inclosure Type: FULLY INCLOSED
  • Body Outside Diameter: 80.0 MILLIMETERS NOMINAL MM
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: TERMINAL SINGLE GROUP
  • Winding Function and Quantity: 2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
  • Winding Shielding Method: GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
  • Features Provided: COLOR CODED LEAD
Identification
  • NSN: 5950-01-356-1320
  • NIIN: 013561320
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-356-1320, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 20 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-356-1320
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Inclosure TypeFULLY INCLOSED
Body Outside Diameter80.0 MILLIMETERS NOMINAL MM
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTERMINAL SINGLE GROUP
Winding Function and Quantity2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Winding Shielding MethodGROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Features ProvidedCOLOR CODED LEAD
Body Length40.0 MILLIMETERS NOMINAL MM
Winding Operating Current0.54 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current0.54 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current0.72 AMPERES AC NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Current0.72 AMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM SINGLE COMPONENT
Winding Operating Voltage24.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage24.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
Winding Operating Voltage18.40 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage18.40 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Terminal Type and Quantity13 WIRE LEAD
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
53608-56700 3/9 Design control — primary reference
Neutrik Instrumentation Inc
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-356-1320?

NSN 5950-01-356-1320 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-356-1320?

Key specifications for 5950-01-356-1320: Inclosure Type: FULLY INCLOSED; Body Outside Diameter: 80.0 MILLIMETERS NOMINAL MM; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: TERMINAL SINGLE GROUP. 20 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-356-1320 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com