PartsTable TECHNICAL DATA SHEET
NSN 5950-01-346-9705Government record, cited

Transformer, Power5950-01-346-9705

NSN 5950-01-346-9705 · NIIN 013469705
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-346-9705 · 5950013469705 · NIIN 013469705 · 01-346-9705 · FSC 5950 Coils and Transformers · 3-401020 · 007252
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: WYE-DELTA-WYE
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT
  • Mounting Method: TERMINAL SINGLE GROUP
  • Winding Function and Quantity: 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
  • Winding Shielding Method: INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Identification
  • NSN: 5950-01-346-9705
  • NIIN: 013469705
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-346-9705, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-346-9705
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Transformer Winding Connection TypeWYE-DELTA-WYE
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE SINGLE COMPONENT
Mounting MethodTERMINAL SINGLE GROUP
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Maximum Operating Temp170.0 CELSIUS DEGC
Winding Operating Current18.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
Winding Operating Current18.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage20.80 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
Terminal Type and Quantity6 TAB, SOLDER LUG AND 5 THREADED STUD
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
3-401020 5/9 Secondary reference
Dytek Laboratories
007252 3/9 Design control — primary reference
Ge Aviation Systems Llc Dba Ge Aviation Systems Llc
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-346-9705?

NSN 5950-01-346-9705 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-346-9705?

Key specifications for 5950-01-346-9705: Overall Height: 3.130 INCHES MAXIMUM IN; Transformer Winding Connection Type: WYE-DELTA-WYE; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 16 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-346-9705 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com