PartsTable TECHNICAL DATA SHEET
NSN 5950-01-345-3690Government record, cited

Transformer, Power5950-01-345-3690

NSN 5950-01-345-3690 · NIIN 013453690
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-345-3690 · 5950013453690 · NIIN 013453690 · 01-345-3690 · FSC 5950 Coils and Transformers · 0365-4028 · 0365-4028
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Inclosure Type: OPEN
  • Body Outside Diameter: 2.719 INCHES NOMINAL IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: TERMINAL SINGLE GROUP
  • Winding Function and Quantity: 2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
  • Winding Shielding Method: INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
  • Winding Operating Current: 0.114 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Identification
  • NSN: 5950-01-345-3690
  • NIIN: 013453690
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-345-3690, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-345-3690
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Inclosure TypeOPEN
Body Outside Diameter2.719 INCHES NOMINAL IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTERMINAL SINGLE GROUP
Winding Function and Quantity2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
Winding Operating Current0.114 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current0.203 AMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current0.47 AMPERES AC NOMINAL SINGLE COMPONENT SECOND PRIMARY
Winding Operating Current0.647 AMPERES AC NOMINAL SINGLE COMPONENT FIRST PRIMARY
Winding Operating Current5.3 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY
Winding Operating Voltage23.12 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage34.27 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage36.75 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage5.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY
Terminal Type and Quantity15 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
0365-4028 C/1 Advisory reference — outside the item-of-supply concept
Iet Labs Inc
0365-4028 3/9 Design control — primary reference
Genrad Inc
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-345-3690?

NSN 5950-01-345-3690 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-345-3690?

Key specifications for 5950-01-345-3690: Inclosure Type: OPEN; Body Outside Diameter: 2.719 INCHES NOMINAL IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: TERMINAL SINGLE GROUP. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-345-3690 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com