The Coil,electrical, cataloged under National Stock Number 5950-01-324-4306, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations. Government technical data includes 20 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-324-4306 |
| Primary Part Number | 727967-1 |
| Item Name | Coil,electrical |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Overall Diameter | 1.200 INCHES MAXIMUM IN |
| Mounting Method | TERMINAL SINGLE GROUP |
| Inductance Rating | 0.725 MILLIHENRIES MINIMUM AND 1.09 MILLIHENRIES MAXIMUM SINGLE COMPONENT FIRST WINDING |
| Inductance Rating | 2.89 MILLIHENRIES MINIMUM AND 4.34 MILLIHENRIES MAXIMUM SINGLE COMPONENT SECOND WINDING |
| Maximum Operating Temp | 120.0 CELSIUS DEGC |
| Body Length | 0.600 INCHES MAXIMUM IN |
| Winding Operating Current | 2.5 AMPERES DC NOMINAL SINGLE COMPONENT FIRST WINDING |
| Winding Operating Current | 500.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SECOND WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT ALL WINDING |
| DC Resistance Rating in Ohms | 0.380 SINGLE COMPONENT FIRST WINDING |
| DC Resistance Rating in Ohms | 1.280 SINGLE COMPONENT SECOND WINDING |
| Reliability Indicator | NOT ESTABLISHED |
| Core Construction | S0LID SINGLE COMPONENT |
| Winding Quantity | 2 SINGLE COMPONENT |
| Frequency Rating | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| Test Data Document | 16340-11-00094 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| Winding Operating Voltage | 17.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST WINDING |
| Winding Operating Voltage | 31.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND WINDING |
| Terminal Type and Quantity | 4 WIRE LEAD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 11-00094-001 | General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations (USA) |
| 727967-1 PRIMARY | General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations (USA) |
| Reference | Meaning |
|---|---|
| 11-00094-001 | 3/9 Design control — primary reference Pacific Electro Dynamics Inc Sub of Rockcor Co York Center |
NSN 5950-01-324-4306 is a Coil,electrical, manufactured by General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-01-324-4306 has 2 manufacturer part numbers on file: 11-00094-001 (General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations), 727967-1 (General Dynamics Ots (aerospace), Inc. Dba General Dynamics Ordinance and Tactical Systems Div Seattle Operations).
Key specifications for 727967-1: Inclosure Type: FULLY INCLOSED; Overall Diameter: 1.200 INCHES MAXIMUM IN; Mounting Method: TERMINAL SINGLE GROUP; Inductance Rating: 0.725 MILLIHENRIES MINIMUM AND 1.09 MILLIHENRIES MAXIMUM SINGLE COMPONENT FIRST WINDING. 20 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.