PartsTable TECHNICAL DATA SHEET
NSN 5950-01-320-3609Government record, cited

Transformer, Pulse5950-01-320-3609

NSN 5950-01-320-3609 · NIIN 013203609
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-320-3609 · 5950013203609 · NIIN 013203609 · 01-320-3609 · FSC 5950 Coils and Transformers · MIL-T-21038/11 · M21038/11-005
Nearby stock numbers  ·
Features
  • Transformer,pulse — FSC 5950
  • Inclosure Type: FULLY INCLOSED
  • Body Outside Diameter: 0.375 INCHES NOMINAL IN
  • Mounting Method: TERMINAL SINGLE GROUP
  • Winding Function and Quantity: 2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
  • Impedance Rating in Ohms: 100.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
  • Features Provided: COLOR CODED LEAD AND TINNED WIRE LEADS
  • Specification/standard Data: 81349-MIL-T-21038/11 GOVERNMENT SPECIFICATION
Identification
  • NSN: 5950-01-320-3609
  • NIIN: 013203609
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,pulse, cataloged under National Stock Number 5950-01-320-3609, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-320-3609
Item NameTransformer,pulse
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Inclosure TypeFULLY INCLOSED
Body Outside Diameter0.375 INCHES NOMINAL IN
Mounting MethodTERMINAL SINGLE GROUP
Winding Function and Quantity2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Impedance Rating in Ohms100.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Features ProvidedCOLOR CODED LEAD AND TINNED WIRE LEADS
Specification/standard Data81349-MIL-T-21038/11 GOVERNMENT SPECIFICATION
Maximum Operating Temp130.0 CELSIUS DEGC
Body Length0.375 INCHES NOMINAL IN
DC Resistance Rating in Ohms1.300 SINGLE COMPONENT SINGLE SECONDARY
DC Resistance Rating in Ohms3.700 SINGLE COMPONENT FIRST PRIMARY
DC Resistance Rating in Ohms4.400 SINGLE COMPONENT SECOND PRIMARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating12.0 KILOHERTZ MINIMUM AND 2.3 MEGAHERTZ MAXIMUM SINGLE COMPONENT
Test Data Document81349-MIL-T-21038 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Primary to Secondary Turn Ratio4 TO 4 TO 1 SINGLE COMPONENT
Winding Operating Voltage7.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Terminal Type and Quantity6 WIRE LEAD
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-T-21038/11 4/1 Identification reference
U.S. Government activity
M21038/11-005 2/2 Government specification standardization
U.S. Government activity

Frequently Asked Questions

What is NSN 5950-01-320-3609?

NSN 5950-01-320-3609 is a Transformer,pulse, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-320-3609?

Key specifications for 5950-01-320-3609: Inclosure Type: FULLY INCLOSED; Body Outside Diameter: 0.375 INCHES NOMINAL IN; Mounting Method: TERMINAL SINGLE GROUP; Winding Function and Quantity: 2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-320-3609 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com