PartsTable TECHNICAL DATA SHEET
NSN 5950-01-315-5464Government record, cited

Transformer, Pulse5950-01-315-5464

NSN 5950-01-315-5464 · NIIN 013155464
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-315-5464 · 5950013155464 · NIIN 013155464 · 01-315-5464 · FSC 5950 Coils and Transformers · 841251-2 · 841651-0001 · EP162996
Nearby stock numbers  ·
Features
  • Transformer,pulse — FSC 5950
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Mounting Method: TERMINAL SINGLE GROUP
  • Inductance Rating: 10.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY
  • Body Height: 0.400 INCHES NOMINAL IN
  • Winding Function and Quantity: 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
  • Winding Shielding Method: INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Identification
  • NSN: 5950-01-315-5464
  • NIIN: 013155464
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,pulse, cataloged under National Stock Number 5950-01-315-5464, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 15 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-315-5464
Item NameTransformer,pulse
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Mounting MethodTERMINAL SINGLE GROUP
Inductance Rating10.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY
Body Height0.400 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Features ProvidedTINNED WIRE LEADS
Maximum Operating Temp85.0 CELSIUS DEGC
DC Resistance Rating in Ohms14.000 SINGLE COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Center to Center Distance Between Mounting Facilities Parallel to Width0.300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Primary to Secondary Turn Ratio1 TO 1 SINGLE COMPONENT
Terminal Type and Quantity7 WIRE LEAD
Hazardous Locations/environmental ProtectionSALT SPRAY RESISTANT AND VIBRATION RESISTANT
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL B — Remove Demilitarization Key Points
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
841251-2 3/9 Design control — primary reference
Litton Systems Inc. Div Navigation Systems Division
841651-0001 C/1 Advisory reference — outside the item-of-supply concept
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
EP162996 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-315-5464?

NSN 5950-01-315-5464 is a Transformer,pulse, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-315-5464?

Key specifications for 5950-01-315-5464: Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: TERMINAL SINGLE GROUP; Inductance Rating: 10.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY. 15 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-315-5464 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5950-01-315-5464?

NSN 5950-01-315-5464 has DEMIL Code B. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com