The Transformer,power, cataloged under National Stock Number 5950-01-312-6744, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 20 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-312-6744 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 1 SECOND GROUP |
| Mounting Facility Quantity | 2 FIRST GROUP |
| Inclosure Type | FULLY INCLOSED |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | SLOT FIRST GROUP |
| Mounting Method | UNTHREADED HOLE(S) SECOND GROUP |
| Body Width | 11.750 INCHES NOMINAL IN |
| Maximum Transformer Power Rating | 10.0 KILOVOLT-AMPERE SINGLE COMPONENT |
| Mounting Hole Diameter | 0.562 INCHES NOMINAL SECOND GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Distance Between Mounting Facility Centers | 4.750 INCHES NOMINAL FIRST MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Body Length | 9.750 INCHES NOMINAL IN |
| Winding Operating Current | 83.3 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Current | 83.3 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| Winding Operating Voltage | 109.00 AC VOLTS NOMINAL AND 114.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 126.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 109.00 AC VOLTS NOMINAL AND 114.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL AND 126.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Terminal Type and Quantity | 8 WIRE LEAD |
| Mounting Slot Width | 0.312 INCHES NOMINAL FIRST GROUP IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| A-612375-A-3 | 3/9 Design control — primary reference Schneider Electric Usa, Inc. Dba Schneider Electric |
| A-612375-A-3 | C/1 Advisory reference — outside the item-of-supply concept Square D Co Sorgel Mfg Plant |
| 612375 | 5/9 Secondary reference Square D Co Sorgel Mfg Plant |
NSN 5950-01-312-6744 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-312-6744: Overall Height: 14.750 INCHES NOMINAL IN; Mounting Facility Quantity: 1 SECOND GROUP; Mounting Facility Quantity: 2 FIRST GROUP; Inclosure Type: FULLY INCLOSED. 20 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.