The Transformer,power, cataloged under National Stock Number 5950-01-289-3340, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 11 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-289-3340 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
| Maximum Transformer Power Rating | 42.0 VOLT-AMPERE SINGLE COMPONENT |
| Winding Function and Quantity | 2 PRIMARY AND 5 SECONDARY SINGLE COMPONENT |
| Winding Operating Current | 100.0 MILLIAMPERES AC MINIMUM AND 750.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY INPUT |
| Winding Operating Voltage | 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY INPUT |
| Winding Operating Voltage | 8.90 AC VOLTS MINIMUM AND 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| Terminal Type and Quantity | 14 TAB, SOLDER LUG |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 9271MC-4-1507A | 3/9 Design control — primary reference Aeire Corp |
NSN 5950-01-289-3340 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-289-3340: Overall Height: 2.812 INCHES NOMINAL IN; Inclosure Type: FULLY INCLOSED; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS; Maximum Transformer Power Rating: 42.0 VOLT-AMPERE SINGLE COMPONENT. 11 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.