PartsTable TECHNICAL DATA SHEET
NSN 5950-01-274-6416Government record, cited

Transformer, Power5950-01-274-6416

NSN 5950-01-274-6416 · NIIN 012746416
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-274-6416 · 5950012746416 · NIIN 012746416 · 01-274-6416 · FSC 5950 Coils and Transformers · M27/291-01 · MIL-T-27/291
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 1 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Overall Diameter: 1.782 INCHES MINIMUM AND 1.844 INCHES MAXIMUM IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Winding Function and Quantity: 1 PRIMARY AND 8 SECONDARY SINGLE COMPONENT
  • Winding Shielding Method: INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
Identification
  • NSN: 5950-01-274-6416
  • NIIN: 012746416
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-274-6416, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-274-6416
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity1 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Overall Diameter1.782 INCHES MINIMUM AND 1.844 INCHES MAXIMUM IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Winding Function and Quantity1 PRIMARY AND 8 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Specification/standard Data81349-MIL-T-27/291 GOVERNMENT SPECIFICATION
Maximum Operating Temp130.0 CELSIUS DEGC
Winding Operating Current1.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
Winding Operating Current6.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating17.0 KILOHERTZ MINIMUM AND 23.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
Test Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Winding Operating Voltage26.51 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
Winding Operating Voltage36.76 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity18 TAB, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
M27/291-01 2/2 Government specification standardization
U.S. Government activity
MIL-T-27/291 4/1 Identification reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5950-01-274-6416?

NSN 5950-01-274-6416 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-274-6416?

Key specifications for 5950-01-274-6416: Mounting Facility Quantity: 1 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Overall Diameter: 1.782 INCHES MINIMUM AND 1.844 INCHES MAXIMUM IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-274-6416 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com