PartsTable TECHNICAL DATA SHEET
NSN 5950-01-274-6414Government record, cited

Transformer, Power5950-01-274-6414

NSN 5950-01-274-6414 · NIIN 012746414
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-274-6414 · 5950012746414 · NIIN 012746414 · 01-274-6414 · FSC 5950 Coils and Transformers · MET430 · MIL-T-27/180 · MIL-PRF-27/180 · 58930-1 · M27/180-01
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 25.2 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 1.937 INCHES MINIMUM AND 2.062 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-274-6414
  • NIIN: 012746414
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-274-6414, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 22 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-274-6414
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating25.2 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width1.937 INCHES MINIMUM AND 2.062 INCHES MAXIMUM IN
Body Height2.937 INCHES MINIMUM AND 3.125 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Specification/standard Data81349-MIL-T-27/180 GOVERNMENT SPECIFICATION
Maximum Operating Temp130.0 CELSIUS DEGC
Body Length2.187 INCHES MINIMUM AND 2.312 INCHES MAXIMUM IN
Winding Operating Current2.0 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Test Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Winding Operating Voltage12.60 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
Winding Operating Voltage57.50 AC VOLTS NOMINAL AND 99.70 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity9 TAB, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MET430 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
MIL-T-27/180 5/9 Secondary reference
U.S. Government activity
MIL-PRF-27/180 4/1 Identification reference
U.S. Government activity
58930-1 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
M27/180-01 2/2 Government specification standardization
U.S. Government activity

Frequently Asked Questions

What is NSN 5950-01-274-6414?

NSN 5950-01-274-6414 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-274-6414?

Key specifications for 5950-01-274-6414: Overall Height: 3.562 INCHES MAXIMUM IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 22 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-274-6414 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com