The Transformer,power, cataloged under National Stock Number 5950-01-260-8636, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier. Government technical data includes 19 specifications, cited from the U.S. Government catalog. The record lists 4 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-260-8636 |
| Primary Part Number | 917AS6321 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier |
| Status | ACTIVE |
| Transformer Winding Connection Type | WYE-DELTA AND WYE-WYE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED HOLE(S) SINGLE GROUP |
| Body Width | 2.000 INCHES MAXIMUM IN |
| Body Height | 1.500 INCHES MAXIMUM IN |
| Winding Function and Quantity | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Nominal Thread Size | 0.138 INCHES SINGLE GROUP IN |
| Body Length | 2.000 INCHES MAXIMUM IN |
| Winding Operating Current | 350.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 113.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 5.90 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
| Terminal Type and Quantity | 10 TURRET |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 917AS6321 PRIMARY | Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier (USA) |
| 8C6480 | Raytheon Company (USA) |
| 8C6480 | Raytheon Company Dba Raytheon Co (USA) |
| 26852 | Torotel, Inc. Div Torotel Products, Inc. (USA) |
| Reference | Meaning |
|---|---|
| 8C6480 | 5/9 Secondary reference Raytheon Company Div Corp |
NSN 5950-01-260-8636 is a Transformer,power, manufactured by Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-01-260-8636 has 4 manufacturer part numbers on file: 917AS6321 (Naval Air Systems Command Managed Original Design Activity Not Material/parts Supplier), 8C6480 (Raytheon Company), 8C6480 (Raytheon Company Dba Raytheon Co), 26852 (Torotel, Inc. Div Torotel Products, Inc.).
1 possible match (shared part number, not a government interchangeability claim): 5365-01-344-4285. Verify interchangeability with system specifications before substitution.
Key specifications for 917AS6321: Transformer Winding Connection Type: WYE-DELTA AND WYE-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.