Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: DELTA-WYE
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO SIX PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Body Width: 1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-260-0533
  • NIIN: 012600533
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-260-0533, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-260-0533
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Transformer Winding Connection TypeDELTA-WYE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO SIX PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM IN
Body Height1.730 INCHES MINIMUM AND 1.770 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Features ProvidedCOLOR CODED LEAD AND TINNED WIRE LEADS
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Maximum Operating Temp85.0 CELSIUS DEGC
Body Length1.860 INCHES MINIMUM AND 1.900 INCHES MAXIMUM IN
Winding Operating Current4.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current220.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width0.870 INCHES MINIMUM AND 0.890 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage195.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage22.40 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage9.80 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity16 WIRE LEAD
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
243223P1 3/2 Design control — primary reference
U.S. Government activity
5905962G1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-260-0533?

NSN 5950-01-260-0533 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-260-0533?

Key specifications for 5950-01-260-0533: Transformer Winding Connection Type: DELTA-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-260-0533 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com