The Reactor, cataloged under National Stock Number 5950-01-254-8113, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Div Rmd Strategic. Government technical data includes 16 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-254-8113 |
| Primary Part Number | 5034-110 |
| Item Name | Reactor |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Manufacturer | Raytheon Company Div Rmd Strategic |
| Status | ACTIVE |
| Mounting Facility Quantity | 1 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Body Outside Diameter | 1.000 INCHES MAXIMUM IN |
| Mounting Method | UNTHREADED HOLE(S) SINGLE GROUP |
| Inductance Rating | 3.40 MILLIHENRIES MINIMUM AND 4.30 MILLIHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| Mounting Hole Diameter | 0.200 INCHES MINIMUM SINGLE GROUP IN |
| Maximum Operating Temp | 125.0 CELSIUS DEGC |
| Body Length | 0.510 INCHES MAXIMUM IN |
| Winding Operating Current | 450.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
| DC Resistance Rating in Ohms | 0.800 SINGLE COMPONENT SINGLE WINDING |
| Reliability Indicator | NOT ESTABLISHED |
| Winding Quantity | 1 SINGLE COMPONENT |
| Frequency Rating | 60.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| Terminal Type and Quantity | 2 WIRE LEAD |
| Inductance Type | SWINGING |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 5034-110 | Raytheon Company Div Rmd Strategic (USA) |
| Reference | Meaning |
|---|---|
| 1C7828-1 | 3/2 Design control — primary reference U.S. Government activity |
| 4C3582-1 | 5/2 Secondary reference U.S. Government activity |
NSN 5950-01-254-8113 is a Reactor, manufactured by Raytheon Company Div Rmd Strategic, classified under FSC 5950, Coils and Transformers. Status: active.
NSN 5950-01-254-8113 has 1 manufacturer part number on file: 5034-110 (Raytheon Company Div Rmd Strategic).
1 possible match (shared part number, not a government interchangeability claim): 5998-01-256-2488. Verify interchangeability with system specifications before substitution.
Key specifications for 5034-110: Mounting Facility Quantity: 1 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Body Outside Diameter: 1.000 INCHES MAXIMUM IN; Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.