PartsTable TECHNICAL DATA SHEET
NSN 5950-01-253-4901Government record, cited

Transformer, Power5950-01-253-4901

NSN 5950-01-253-4901 · NIIN 012534901
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-253-4901 · 5950012534901 · NIIN 012534901 · 01-253-4901 · FSC 5950 Coils and Transformers · 2914208-1 · 291420-1
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Winding Function and Quantity: 1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT
  • Nominal Thread Size: 0.164 INCHES SINGLE GROUP IN
Identification
  • NSN: 5950-01-253-4901
  • NIIN: 012534901
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-253-4901, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-253-4901
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Winding Function and Quantity1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Winding Operating Current1.23 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current1.23 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current1.64 AMPERES AC MAXIMUM SINGLE COMPONENT SIXTH SECONDARY
Winding Operating Current13.12 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current2.05 AMPERES AC MAXIMUM SINGLE COMPONENT FIFTH SECONDARY
Winding Operating Current2.05 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage12.00 AC VOLTS NOMINAL SINGLE COMPONENT SIXTH SECONDARY
Winding Operating Voltage176.70 AC VOLTS MINIMUM AND 214.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage18.14 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage18.14 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage24.20 AC VOLTS NOMINAL SINGLE COMPONENT FIFTH SECONDARY
Winding Operating Voltage24.20 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage7.85 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Terminal Type and Quantity24 TAB, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
2914208-1 3/2 Design control — primary reference
U.S. Government activity
291420-1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-253-4901?

NSN 5950-01-253-4901 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-253-4901?

Key specifications for 5950-01-253-4901: Overall Height: 3.940 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 25 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-253-4901 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com