PartsTable TECHNICAL DATA SHEET
NSN 5950-01-244-8376Government record, cited

Transformer, Power5950-01-244-8376

NSN 5950-01-244-8376 · NIIN 012448376 · Part number LO3542
Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 16236
Government record, cited
NSN 5950-01-244-8376 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-244-8376. Manufacturer of record part number: LO3542.
Also searched as  5950-01-244-8376 · 5950012448376 · NIIN 012448376 · 01-244-8376 · FSC 5950 Coils and Transformers · CAGE 16236 · LO3542 · KDW2301-1 · KDW2301-1
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 ALL GROUPINGS
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SECOND CENTER GROUP IN
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.562 INCHES NOMINAL SINGLE MOUNTING FACILITY FIRST CENTER GROUP IN
  • Winding Power Rating: 101.1 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
  • Winding Power Rating: 220.0 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Identification
  • NSN: 5950-01-244-8376
  • NIIN: 012448376
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: LO3542
  • Manufacturer: Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-244-8376, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings). Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-244-8376
Primary Part NumberLO3542
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerDla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)
StatusACTIVE
Mounting Facility Quantity4 ALL GROUPINGS
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SECOND CENTER GROUP IN
Center to Center Distance Between Mounting Facilities Parallel to Length2.562 INCHES NOMINAL SINGLE MOUNTING FACILITY FIRST CENTER GROUP IN
Winding Power Rating101.1 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
Winding Power Rating220.0 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) ALL GROUPINGS
Body Width3.600 INCHES MAXIMUM IN
Body Height5.220 INCHES MAXIMUM IN
Maximum Transformer Power Rating321.1 VOLT-AMPERE SINGLE COMPONENT
Criticality Code JustificationZZZY
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Nominal Thread Size0.190 INCHES ALL GROUPINGS IN
Maximum Operating Temp155.0 CELSIUS DEGC
Body Length5.250 INCHES MAXIMUM IN
Winding Operating Current1.0 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current3.0 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SECOND CENTER GROUP IN
Center to Center Distance Between Mounting Facilities Parallel to Width2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY FIRST CENTER GROUP IN
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage220.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage33.70 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity1 TERMINAL BLOCK W/SCREWS
Thread Series DesignatorUNF ALL GROUPINGS
Reference Number Differentiating CharacteristicsREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeS
Cross-Reference Index
Part NumberManufacturer
LO3542 Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) (USA)
Reference documents
ReferenceMeaning
KDW2301-1 3/1 Design control — primary reference
Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc
KDW2301-1 5/9 Secondary reference
Eaton Aerospace Llc Dba Eaton Inoac Div Fluid & Electrical Distribution
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-244-8376?

NSN 5950-01-244-8376 is a Transformer,power, manufactured by Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings), classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-244-8376?

NSN 5950-01-244-8376 has 1 manufacturer part number on file: LO3542 (Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)).

What are the specifications of LO3542?

Key specifications for LO3542: Mounting Facility Quantity: 4 ALL GROUPINGS; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SECOND CENTER GROUP IN; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.562 INCHES NOMINAL SINGLE MOUNTING FACILITY FIRST CENTER GROUP IN. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-244-8376 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com