PartsTable TECHNICAL DATA SHEET
NSN 5950-01-244-8369Government record, cited

Reactor5950-01-244-8369

NSN 5950-01-244-8369 · NIIN 012448369 · Part number L03543
Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 16236
Government record, cited
NSN 5950-01-244-8369 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-244-8369. Manufacturer of record part number: L03543.
Also searched as  5950-01-244-8369 · 5950012448369 · NIIN 012448369 · 01-244-8369 · FSC 5950 Coils and Transformers · CAGE 16236 · L03543 · KEH2301-1 · KEH2301-1
Nearby stock numbers  ·
Features
  • Reactor — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Turn Quantity: 385 SINGLE COMPONENT SINGLE WINDING
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Inductance Rating: 330.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
  • Body Width: 3.000 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-244-8369
  • NIIN: 012448369
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: L03543
  • Manufacturer: Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)
General Description

The Reactor, cataloged under National Stock Number 5950-01-244-8369, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings). Government technical data includes 23 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-244-8369
Primary Part NumberL03543
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerDla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length4.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Turn Quantity385 SINGLE COMPONENT SINGLE WINDING
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Inductance Rating330.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
Body Width3.000 INCHES NOMINAL IN
Body Height2.600 INCHES NOMINAL IN
Winding Conductor Size0.03196 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING IN
Criticality Code JustificationFEAT
Nominal Thread Size0.190 INCHES SINGLE GROUP IN
Maximum Operating Temp155.0 CELSIUS DEGC
Body Length5.700 INCHES MAXIMUM IN
Winding Operating Current2.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
Rating MethodELECTRICAL AND WINDING TURNS SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms3.800 SINGLE COMPONENT SINGLE WINDING
Reliability IndicatorNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Terminal Type and Quantity2 PIN
Inductance TypeFIXED
Thread Series DesignatorUNF SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeS
Cross-Reference Index
Part NumberManufacturer
L03543 PRIMARY Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) (USA)
Reference documents
ReferenceMeaning
KEH2301-1 3/1 Design control — primary reference
Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc
KEH2301-1 5/9 Secondary reference
Eaton Aerospace Llc Dba Eaton Inoac Div Fluid & Electrical Distribution
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-244-8369?

NSN 5950-01-244-8369 is a Reactor, manufactured by Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings), classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-244-8369?

NSN 5950-01-244-8369 has 1 manufacturer part number on file: L03543 (Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)).

What are the specifications of L03543?

Key specifications for L03543: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Turn Quantity: 385 SINGLE COMPONENT SINGLE WINDING. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-244-8369 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com