The Transformer,power, cataloged under National Stock Number 5950-01-237-4270, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-237-4270 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | UNTHREADED HOLE(S) SINGLE GROUP |
| Mounting Hole Diameter | 0.169 INCHES NOMINAL SINGLE GROUP IN |
| Winding Function and Quantity | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
| Winding Operating Current | 0.06 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Winding Operating Current | 0.38 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 0.38 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 3.12 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Current | 8.4 AMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Reliability Indicator | NOT ESTABLISHEDNOT ESTABLISHED |
| Frequency Rating | 25.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 102.76 DC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 102.76 DC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 17.60 DC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 326.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 7.10 DC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Terminal Type and Quantity | 11 TURRET |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| TT12468 | 3/9 Design control — primary reference Magnetika/east Ltd Titan Transformer Div |
| 55-1345344-1 | 5/9 Secondary reference Gte Government Systems Corp Strategic Systems Div |
NSN 5950-01-237-4270 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-237-4270: Overall Height: 2.130 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 21 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.