The Transformer,power, cataloged under National Stock Number 5950-01-237-3406, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-237-3406 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Power Rating | 120.0 WATTS SINGLE COMPONENT FIRST SECONDARY |
| Winding Power Rating | 120.0 WATTS SINGLE COMPONENT SECOND SECONDARY |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED STUD(S) SINGLE GROUP |
| Winding Function and Quantity | 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT |
| Nominal Thread Size | 0.250 INCHES SINGLE GROUP IN |
| Winding Operating Current | 250.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 0.6 AMPERES AC MAXIMUM SINGLE COMPONENT FIFTH SECONDARY |
| Winding Operating Current | 250.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Current | 50.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 24.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 24.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 24.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 11.00 AC VOLTS NOMINAL SINGLE COMPONENT FIFTH SECONDARY |
| Winding Operating Voltage | 75.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Terminal Type and Quantity | 18 TURRET |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 109-072-001 | 3/9 Design control — primary reference Aydin Corp Aydin Controls Div |
NSN 5950-01-237-3406 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-237-3406: Overall Height: 5.500 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 25 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.