The Transformer,power Autotransforme, cataloged under National Stock Number 5950-01-229-4467, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 8 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-229-4467 |
| Item Name | Transformer,power Autotransforme |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSEDFULLY INCLOSED |
| Winding Power Rating | 500.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| Winding Function and Quantity | 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
| Winding Operating Current | 4.3 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| Reliability Indicator | NOT ESTABLISHED |
| Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
| Winding Operating Voltage | 16.40 AC VOLTS NOMINAL AND 32.80 AC VOLTS NOMINAL AND 49.20 AC VOLTS NOMINAL AND 65.60 AC VOLTS NOMINAL AND 82.00 AC VOLTS NOMINAL AND 98.40 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
| Terminal Type and Quantity | 8 TAB, SOLDER LUG |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 5950PL0944001 | 6/9 Informative reference only Jednolity Indeks Materialowy - Uniform Material Index |
| T61950 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-01-229-4467 is a Transformer,power Autotransforme, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-229-4467: Inclosure Type: FULLY INCLOSEDFULLY INCLOSED; Winding Power Rating: 500.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT; Winding Function and Quantity: 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT; Winding Operating Current: 4.3 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT. 8 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.