The Transformer,power, cataloged under National Stock Number 5950-01-225-5697, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-225-5697 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | SLOT SINGLE GROUP |
| Body Width | 6.375 INCHES NOMINAL IN |
| Body Height | 5.375 INCHES NOMINAL IN |
| Maximum Transformer Power Rating | 750.0 VOLT-AMPERE SINGLE COMPONENT |
| Winding Function and Quantity | 2 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Body Length | 6.344 INCHES NOMINAL IN |
| Winding Operating Current | 6.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 5.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 95.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Winding Operating Voltage | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY |
| Winding Operating Voltage | 230.00 AC VOLTS NOMINAL AND 345.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY |
| Terminal Type and Quantity | 8 TAB, SOLDER LUG |
| Mounting Slot Width | 0.312 INCHES NOMINAL SINGLE GROUP IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| W750 FORM A | 3/9 Design control — primary reference Hevi Duty Electric Sola Basic Industries Inc Div a Unit of General Signal Corp |
NSN 5950-01-225-5697 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-225-5697: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 19 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.