PartsTable TECHNICAL DATA SHEET
NSN 5950-01-223-1126Government record, cited

Transformer, Power5950-01-223-1126

NSN 5950-01-223-1126 · NIIN 012231126
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-223-1126 · 5950012231126 · NIIN 012231126 · 01-223-1126 · FSC 5950 Coils and Transformers · 866277-2 · 866277-1
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: WYE-DELTA
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 152.2 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY
  • Winding Power Rating: 36.6 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
  • Winding Power Rating: 43.0 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
Identification
  • NSN: 5950-01-223-1126
  • NIIN: 012231126
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-223-1126, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-223-1126
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Transformer Winding Connection TypeWYE-DELTA
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating152.2 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY
Winding Power Rating36.6 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
Winding Power Rating43.0 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
Winding Power Rating49.0 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE SINGLE COMPONENT
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Body Width3.150 INCHES MAXIMUM IN
Body Height1.870 INCHES MAXIMUM IN
Maximum Transformer Power Rating280.8 VOLT-AMPERE SINGLE COMPONENT
Winding Function and Quantity1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.138 INCHES SINGLE GROUP IN
Maximum Operating Temp180.0 CELSIUS DEGC
Body Length3.400 INCHES MAXIMUM IN
Winding Operating Current1.8 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current11.0 AMPERES AC NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Current2.1 AMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current820.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage199.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage13.50 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage13.80 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage25.80 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage8.00 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Terminal Type and Quantity16 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
866277-2 3/2 Design control — primary reference
U.S. Government activity
866277-1 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-223-1126?

NSN 5950-01-223-1126 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-223-1126?

Key specifications for 5950-01-223-1126: Transformer Winding Connection Type: WYE-DELTA; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-223-1126 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.