Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 2 SINGLE GROUP
  • Inclosure Type: OPEN
  • Winding Power Rating: 0.636 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY
  • Winding Power Rating: 324.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
  • Winding Power Rating: 39.49 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY
  • Winding Power Rating: 426.4 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
  • Winding Power Rating: 65.75 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
Identification
  • NSN: 5950-01-210-6406
  • NIIN: 012106406
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-210-6406, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-210-6406
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity2 SINGLE GROUP
Inclosure TypeOPEN
Winding Power Rating0.636 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY
Winding Power Rating324.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
Winding Power Rating39.49 VOLTS-AMPERES SINGLE COMPONENT FOURTH SECONDARY
Winding Power Rating426.4 VOLTS-AMPERES SINGLE COMPONENT SECOND SECONDARY
Winding Power Rating65.75 VOLTS-AMPERES SINGLE COMPONENT FIRST SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width0.150 INCHES MAXIMUM IN
Body Height1.660 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 8 SECONDARY SINGLE COMPONENT
Distance Between Mounting Facility Centers1.220 INCHES MINIMUM AND 1.280 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Nominal Thread Size0.112 INCHES SINGLE GROUP IN
Maximum Operating Temp155.0 CELSIUS DEGC
Body Length1.630 INCHES MAXIMUM IN
Winding Operating Current1.7 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Current250.0 MILLIAMPERES AC MINIMUM AND 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Current5.0 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current5.4 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current50.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating50.0 KILOHERTZ NOMINAL SINGLE COMPONENT
Winding Operating Voltage12.72 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage13.15 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage190.89 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage39.49 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage78.98 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity22 TURRET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
SM-C-951600 3/2 Design control — primary reference
U.S. Government activity
5905647G1 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-210-6406?

NSN 5950-01-210-6406 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-210-6406?

Key specifications for 5950-01-210-6406: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: OPEN; Winding Power Rating: 0.636 VOLTS-AMPERES SINGLE COMPONENT THIRD SECONDARY; Winding Power Rating: 324.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-210-6406 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com