The Transformer,pulse, cataloged under National Stock Number 5950-01-198-6278, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-198-6278 |
| Item Name | Transformer,pulse |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Overall Diameter | 0.570 INCHES MAXIMUM IN |
| Mounting Method | TERMINAL SINGLE GROUP |
| Pulse Repetition Rate | 100.0 KILOHERTZ SINGLE COMPONENT |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Impedance Rating in Ohms | 10.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Maximum Operating Temp | 105.0 CELSIUS DEGC |
| Body Length | 0.520 INCHES MAXIMUM IN |
| Mounting Bolt Circle Diameter | 0.265 INCHES MINIMUM AND 0.285 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Current | 1.06 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Winding Operating Voltage | 10.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Winding Operating Voltage | 21.21 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Terminal Type and Quantity | 5 PIN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 366027-1 | 3/2 Design control — primary reference U.S. Government activity |
| 366027-2 | 5/2 Secondary reference U.S. Government activity |
NSN 5950-01-198-6278 is a Transformer,pulse, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-198-6278: Inclosure Type: FULLY INCLOSED; Overall Diameter: 0.570 INCHES MAXIMUM IN; Mounting Method: TERMINAL SINGLE GROUP; Pulse Repetition Rate: 100.0 KILOHERTZ SINGLE COMPONENT. 14 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.