The Transformer,power, cataloged under National Stock Number 5950-01-192-3126, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-192-3126 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | OPEN |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Mounting Method | SLOT SINGLE GROUP |
| Body Width | 3.120 INCHES NOMINAL IN |
| Body Height | 3.750 INCHES NOMINAL IN |
| Winding Function and Quantity | 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Body Length | 4.120 INCHES NOMINAL IN |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 47.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| Terminal Type and Quantity | 14 TAB, SOLDER LUG |
| Mounting Slot Width | 0.190 INCHES NOMINAL SINGLE GROUP IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 500A019-001 | 3/9 Design control — primary reference Andrew Scicomm Inc |
| 500A019-001 | 5/9 Secondary reference California Microwave Inc Communications Receivers Operations |
NSN 5950-01-192-3126 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-192-3126: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: SLOT SINGLE GROUP. 14 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.