PartsTable TECHNICAL DATA SHEET
NSN 5950-01-187-8804Government record, cited

Transformer, Power5950-01-187-8804

NSN 5950-01-187-8804 · NIIN 011878804 · Part number TW-71088
Magnetika · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 02640
Government record, cited
NSN 5950-01-187-8804 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-187-8804. Manufacturer of record part number: TW-71088.
Also searched as  5950-01-187-8804 · 5950011878804 · NIIN 011878804 · 01-187-8804 · FSC 5950 Coils and Transformers · CAGE 02640 · TW-71088 · 166153 · 43373
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Transformer Winding Connection Type: DELTA-DELTA
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: THREE PHASE TO THREE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 3.688 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-187-8804
  • NIIN: 011878804
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: TW-71088
  • Manufacturer: Magnetika
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-187-8804, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Magnetika. Government technical data includes 26 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-187-8804
Primary Part NumberTW-71088
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerMagnetika
StatusACTIVE
Transformer Winding Connection TypeDELTA-DELTA
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipTHREE PHASE TO THREE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width3.688 INCHES NOMINAL IN
Body Height5.562 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
Nominal Thread Size0.190 INCHES SINGLE GROUP IN
Maximum Operating Temp110.0 CELSIUS DEGC
Body Length4.312 INCHES NOMINAL IN
Winding Operating Current1.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current1.5 AMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current1.2 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Current8.0 AMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating54.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage10.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage13.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage19.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity12 TURRET
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
4730-01-341-720543373REVA POSSIBLE MATCH
EXPANSION JOINT,PIPE
Possible match (shared part number)Hyspan Precision Products, Inc.
5360-01-373-254843373 POSSIBLE MATCH
SPRING,HELICAL,COMPRESSION
Possible match (shared part number)Eaton Aerospace Llc Dba Eaton Aerospace Jackson
5120-01-563-3620 POSSIBLE MATCH
HANDLE,SCREWDRIVER
Possible match (shared part number)
Cross-Reference Index
Part NumberManufacturer
TW-71088 PRIMARY Magnetika (USA)
43373 Coast/advanced Chip Magnetics, Inc. (USA)
Reference documents
ReferenceMeaning
166153 7/2 Vendor item drawing reference
Northrop Grumman Systems Corporation
Related Parts
4730-01-341-7205POSSIBLE MATCH
EXPANSION JOINT,PIPE
43373REVA
5360-01-373-2548POSSIBLE MATCH
SPRING,HELICAL,COMPRESSION
43373
5120-01-563-3620POSSIBLE MATCH
HANDLE,SCREWDRIVER

Frequently Asked Questions

What is NSN 5950-01-187-8804?

NSN 5950-01-187-8804 is a Transformer,power, manufactured by Magnetika, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-187-8804?

NSN 5950-01-187-8804 has 2 manufacturer part numbers on file: TW-71088 (Magnetika), 43373 (Coast/advanced Chip Magnetics, Inc.).

What NSN replaces 5950-01-187-8804?

3 possible matches (shared part number, not a government interchangeability claim): 4730-01-341-7205, 5360-01-373-2548, 5120-01-563-3620. Verify interchangeability with system specifications before substitution.

What are the specifications of TW-71088?

Key specifications for TW-71088: Transformer Winding Connection Type: DELTA-DELTA; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-187-8804 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com