The Transformer,power, cataloged under National Stock Number 5950-01-181-1653, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-181-1653 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 0.690 INCHES MINIMUM AND 0.710 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Power Rating | 0.03 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | TERMINAL SINGLE GROUP |
| Body Height | 0.531 INCHES MAXIMUM IN |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Maximum Operating Temp | 105.0 CELSIUS DEGC |
| Winding Operating Current | 3.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 104.00 AC VOLTS MINIMUM AND 124.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 9.985 AC VOLTS MINIMUM AND 10.15 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| Terminal Type and Quantity | 5 PIN |
| Hazardous Locations/environmental Protection | VIBRATION RESISTANT AND MOISTURE RESISTANT |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 732148-1 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-01-181-1653 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-181-1653: Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 0.690 INCHES MINIMUM AND 0.710 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Winding Power Rating: 0.03 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.