The Transformer,power, cataloged under National Stock Number 5950-01-176-5092, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-176-5092 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Inclosure Type | FULLY INCLOSED |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | TERMINAL SINGLE GROUP |
| Body Width | 1.260 INCHES MAXIMUM IN |
| Body Height | 0.550 INCHES MAXIMUM IN |
| Winding Function and Quantity | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| Maximum Operating Temp | 155.0 CELSIUS DEGC |
| Body Length | 1.250 INCHES MINIMUM AND 1.270 INCHES MAXIMUM IN |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 40.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| Winding Operating Voltage | 13.02 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Winding Operating Voltage | 30.40 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 53.56 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Terminal Type and Quantity | 9 WIRE LEAD |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 6569A0003 | 5/9 Secondary reference Technitrol, Inc. Dba Pulse Div Military/aerospace |
| A504A437-101 | 5/9 Secondary reference Opt Industries Inc Div of Electronika Inc |
| A504A437-101 | 3/2 Design control — primary reference U.S. Government activity |
| EWC6569 | 5/9 Secondary reference Technitrol, Inc. Dba Pulse Div Military/aerospace |
NSN 5950-01-176-5092 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-176-5092: Inclosure Type: FULLY INCLOSED; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: TERMINAL SINGLE GROUP; Body Width: 1.260 INCHES MAXIMUM IN. 14 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.