PartsTable TECHNICAL DATA SHEET
NSN 5950-01-166-8006Government record, cited

Transformer, Power5950-01-166-8006

NSN 5950-01-166-8006 · NIIN 011668006
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-166-8006 · 5950011668006 · NIIN 011668006 · 01-166-8006 · FSC 5950 Coils and Transformers · P-8198 · 3605-32-5
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: FLANGE AND SLOT SINGLE GROUP
  • Body Width: 2.188 INCHES NOMINAL IN
  • Body Height: 2.625 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-166-8006
  • NIIN: 011668006
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-166-8006, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-166-8006
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypePARTIALLY INCLOSED, DOUBLE SHELL
Center to Center Distance Between Mounting Facilities Parallel to Length1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodFLANGE AND SLOT SINGLE GROUP
Body Width2.188 INCHES NOMINAL IN
Body Height2.625 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Body Length2.562 INCHES NOMINAL IN
Winding Operating Current0.5 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage54.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Terminal Type and Quantity7 WIRE LEAD
Mounting Slot Width0.188 INCHES NOMINAL SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
P-8198 3/9 Design control — primary reference
U.S. Government activity
3605-32-5 5/1 Secondary reference
King Nutronics Corporation Dba King Nutronics
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-166-8006?

NSN 5950-01-166-8006 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-166-8006?

Key specifications for 5950-01-166-8006: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-166-8006 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com