The Transformer,power, cataloged under National Stock Number 5950-01-165-5364, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-165-5364 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Transformer Winding Connection Type | WYE-DELTA AND WYE-WYE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 1.740 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Input-Output Phase Relationship | THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| Mounting Method | THREADED HOLE(S) SINGLE GROUP |
| Body Width | 1.750 INCHES MAXIMUM IN |
| Body Height | 3.000 INCHES MAXIMUM IN |
| Winding Function and Quantity | 1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT |
| Nominal Thread Size | 0.138 INCHES SINGLE GROUP IN |
| Body Length | 3.100 INCHES MAXIMUM IN |
| Winding Operating Current | 1.23 AMPERES AC NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Current | 2.86 AMPERES AC NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Winding Operating Current | 410.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Current | 6.52 AMPERES AC NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Reliability Indicator | NOT ESTABLISHED |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 1.190 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Winding Operating Voltage | 11.60 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY |
| Winding Operating Voltage | 187.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| Winding Operating Voltage | 20.50 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| Winding Operating Voltage | 20.50 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY |
| Winding Operating Voltage | 43.30 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| Terminal Type and Quantity | 21 TAB, SOLDER LUG |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 593R694A01 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-01-165-5364 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-165-5364: Transformer Winding Connection Type: WYE-DELTA AND WYE-WYE; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.740 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 25 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.