PartsTable TECHNICAL DATA SHEET
NSN 5950-01-165-5359Government record, cited

Transformer, Power5950-01-165-5359

NSN 5950-01-165-5359 · NIIN 011655359
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-165-5359 · 5950011655359 · NIIN 011655359 · 01-165-5359 · FSC 5950 Coils and Transformers · 21570 · M1591
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 4.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 500.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Body Width: 4.380 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-165-5359
  • NIIN: 011655359
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-165-5359, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-165-5359
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypePARTIALLY INCLOSED, DOUBLE SHELL
Center to Center Distance Between Mounting Facilities Parallel to Length4.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating500.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Body Width4.380 INCHES NOMINAL IN
Body Height3.000 INCHES MAXIMUM IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Nominal Thread Size0.164 INCHES SINGLE GROUP IN
Body Length5.250 INCHES NOMINAL IN
Winding Operating Current8.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage26.00 AC VOLTS NOMINAL AND 86.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage92.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity5 TAB, SOLDER LUG
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
4520-01-277-748121570 POSSIBLE MATCH
HEATING ELEMENT,ELECTRICAL,NONIM
Possible match (shared part number)National Oilwell Varco Inc Dba National Oilwell
5330-01-422-595821570 POSSIBLE MATCH
SEAL,PLAIN
Possible match (shared part number)Maradyne Corporation
6520-01-591-80711008.1834 POSSIBLE MATCH
HEAD,DENTAL HANDPIECE
Possible match (shared part number)Kavo Dental Technologies Llc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
21570 3/9 Design control — primary reference
Myers Power Products, Inc. Dba Myers/abacus Div Myers Emergency Power Systems
M1591 5/9 Secondary reference
Myers Power Products, Inc. Dba Myers/abacus Div Myers Emergency Power Systems
Related Parts
4520-01-277-7481POSSIBLE MATCH
HEATING ELEMENT,ELECTRICAL,NONIM
21570
5330-01-422-5958POSSIBLE MATCH
SEAL,PLAIN
21570
6520-01-591-8071POSSIBLE MATCH
HEAD,DENTAL HANDPIECE
1008.1834

Frequently Asked Questions

What is NSN 5950-01-165-5359?

NSN 5950-01-165-5359 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-165-5359?

3 possible matches (shared part number, not a government interchangeability claim): 4520-01-277-7481, 5330-01-422-5958, 6520-01-591-8071. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-165-5359?

Key specifications for 5950-01-165-5359: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: PARTIALLY INCLOSED, DOUBLE SHELL; Center to Center Distance Between Mounting Facilities Parallel to Length: 4.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Winding Power Rating: 500.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-165-5359 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com