PartsTable TECHNICAL DATA SHEET
NSN 5950-01-147-0255Government record, cited

Transformer, Power5950-01-147-0255

NSN 5950-01-147-0255 · NIIN 011470255
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-147-0255 · 5950011470255 · NIIN 011470255 · 01-147-0255 · FSC 5950 Coils and Transformers
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP
  • Winding Function and Quantity: 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
  • Winding Operating Current: 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Identification
  • NSN: 5950-01-147-0255
  • NIIN: 011470255
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-147-0255, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-147-0255
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length3.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodUNTHREADED HOLE(S) SINGLE GROUP
Winding Function and Quantity2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
Winding Operating Current1.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current3.0 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND PRIMARY
Winding Operating Current72.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FIRST PRIMARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating45.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.420 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage62.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage36.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage110.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY
Winding Operating Voltage22.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY
Terminal Type and Quantity11 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
A504T300-101 3/9 Design control — primary reference
Telephone Systems/communications
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-147-0255?

NSN 5950-01-147-0255 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-147-0255?

Key specifications for 5950-01-147-0255: Overall Height: 3.625 INCHES NOMINAL IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-147-0255 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com