PartsTable TECHNICAL DATA SHEET
NSN 5950-01-138-4674Government record, cited

Transformer, Power5950-01-138-4674

NSN 5950-01-138-4674 · NIIN 011384674
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-138-4674 · 5950011384674 · NIIN 011384674 · 01-138-4674 · FSC 5950 Coils and Transformers
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: SLOT SINGLE GROUP
  • Body Width: 3.250 INCHES MAXIMUM IN
  • Body Height: 3.125 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-138-4674
  • NIIN: 011384674
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-138-4674, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-138-4674
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodSLOT SINGLE GROUP
Body Width3.250 INCHES MAXIMUM IN
Body Height3.125 INCHES NOMINAL IN
Winding Function and Quantity2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
Winding Shielding MethodCORE GROUNDED SINGLE COMPONENT
Body Length3.750 INCHES NOMINAL IN
Winding Operating Current200.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current2.25 AMPERES DC MAXIMUM SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Current2.4 AMPERES DC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current800.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage24.00 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND PRIMARY
Winding Operating Voltage19.30 AC VOLTS NOMINAL SINGLE COMPONENT FOURTH SECONDARY
Winding Operating Voltage30.10 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage36.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Winding Operating Voltage93.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST PRIMARY
Terminal Type and Quantity16 TAB, SOLDER LUG
Mounting Slot Width0.250 INCHES NOMINAL SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5950-01-300-2250 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
BX-8433 3/2 Design control — primary reference
U.S. Government activity
Related Parts
5950-01-300-2250POSSIBLE MATCH
TRANSFORMER,POWER

Frequently Asked Questions

What is NSN 5950-01-138-4674?

NSN 5950-01-138-4674 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-138-4674?

1 possible match (shared part number, not a government interchangeability claim): 5950-01-300-2250. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-138-4674?

Key specifications for 5950-01-138-4674: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 25 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-138-4674 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com