PartsTable TECHNICAL DATA SHEET
NSN 5950-01-131-8069Government record, cited

Transformer, Power5950-01-131-8069

NSN 5950-01-131-8069 · NIIN 011318069 · Part number B4007723-1
Department of the Army Hq United States Army Communications Research and Development Command · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 56996
Government record, cited
NSN 5950-01-131-8069 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-131-8069. Manufacturer of record part number: B4007723-1.
Also searched as  5950-01-131-8069 · 5950011318069 · NIIN 011318069 · 01-131-8069 · FSC 5950 Coils and Transformers · CAGE 56996 · B4007723-1 · 4C3391
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 2.520 INCHES MAXIMUM IN
  • Body Height: 2.750 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-131-8069
  • NIIN: 011318069
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: B4007723-1
  • Manufacturer: Department of the Army Hq United States Army Communications Research and Development Command
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-131-8069, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Department of the Army Hq United States Army Communications Research and Development Command. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-131-8069
Primary Part NumberB4007723-1
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerDepartment of the Army Hq United States Army Communications Research and Development Command
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodUNTHREADED HOLE(S) SINGLE GROUP
Body Width2.520 INCHES MAXIMUM IN
Body Height2.750 INCHES MAXIMUM IN
Mounting Hole Diameter0.219 INCHES NOMINAL SINGLE GROUP IN
Winding Function and Quantity1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Maximum Operating Temp155.0 CELSIUS DEGC
Body Length3.060 INCHES MAXIMUM IN
Winding Operating Current700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY
Winding Operating Current700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY
Winding Operating Current2.7 AMPERES AC MAXIMUM SINGLE COMPONENT THIRD SECONDARY
Winding Operating Current565.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating47.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width2.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage16.50 AC VOLTS NOMINAL SINGLE COMPONENT THIRD SECONDARY
Winding Operating Voltage25.75 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY
Winding Operating Voltage25.75 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY
Terminal Type and Quantity12 TAB, SOLDER LUG
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
B4007723-1 PRIMARY Department of the Army Hq United States Army Communications Research and Development Command (USA)
Reference documents
ReferenceMeaning
4C3391 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-131-8069?

NSN 5950-01-131-8069 is a Transformer,power, manufactured by Department of the Army Hq United States Army Communications Research and Development Command, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-131-8069?

NSN 5950-01-131-8069 has 1 manufacturer part number on file: B4007723-1 (Department of the Army Hq United States Army Communications Research and Development Command).

What are the specifications of B4007723-1?

Key specifications for B4007723-1: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-131-8069 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com