The Reactor, cataloged under National Stock Number 5950-01-122-7266, is classified within Federal Supply Class 5950 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Raytheon Company Dba Raytheon. Government technical data includes 22 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 7 commercial cross-references from 6 manufacturers, enabling identification through both NSN and commercial part number lookups. 7 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-122-7266 |
| Primary Part Number | 986260-1B |
| Item Name | Reactor |
| FSC / FSG | 5950 / 59 — No Item Name Available |
| Manufacturer | Raytheon Company Dba Raytheon |
| Status | ACTIVE |
| Mounting Facility Quantity | 4 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Winding Quantity | 2 SINGLE COMPONENT |
| Winding Operating Current | 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT SECOND WINDING |
| Frequency Rating | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| Mounting Method | FLANGE AND UNTHREADED HOLE(S) SINGLE GROUP |
| Mounting Hole Diameter | 0.156 INCHES NOMINAL SINGLE GROUP IN |
| Body Height | 1.180 INCHES MAXIMUM IN |
| Maximum Operating Temp | 130.0 CELSIUS DEGC |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| DC Resistance Rating in Ohms | 0.400 SINGLE COMPONENT SECOND WINDING |
| Rating Method | ELECTRICAL SINGLE COMPONENT FIRST WINDING |
| Reliability Indicator | NOT ESTABLISHED |
| DC Resistance Rating in Ohms | 0.100 SINGLE COMPONENT FIRST WINDING |
| Inductance Type | FIXED |
| Body Length | 3.000 INCHES NOMINAL IN |
| Inductance Rating | 1.00 MILLIHENRIES NOMINAL SINGLE COMPONENT ALL WINDING |
| Winding Operating Current | 20.0 AMPERES DC MAXIMUM SINGLE COMPONENT FIRST WINDING |
| Body Width | 2.750 INCHES MAXIMUM IN |
| Center to Center Distance Between Mounting Facilities Parallel to Width | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Terminal Type and Quantity | 4 TAB, SOLDER LUG |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 10132767 | Nimikkeistokeskus Ncb Finland (FIN) |
| WE-3223 | Wems Electronics Transformer Group (USA) |
| 315-18024-01 | Oeco, Llc Dba Pacific Scientific Oeco Div Fire Safety and Power Systems (USA) |
| 986260-1B PRIMARY | Raytheon Company Dba Raytheon (USA) |
| 18533 | Robert M. Hadley Company, Inc. (USA) |
| WE-3223 | Magnetika Inc (USA) |
| 861918 | Raytheon Company Dba Raytheon (USA) |
NSN 5950-01-122-7266 is a Reactor, manufactured by Raytheon Company Dba Raytheon, classified under FSC 5950 (No Item Name Available). Status: active.
NSN 5950-01-122-7266 has 7 cross-referenced part numbers: 10132767 (Nimikkeistokeskus Ncb Finland), WE-3223 (Wems Electronics Transformer Group), 315-18024-01 (Oeco, Llc Dba Pacific Scientific Oeco Div Fire Safety and Power Systems), 986260-1B (Raytheon Company Dba Raytheon), 18533 (Robert M. Hadley Company, Inc.) and 2 more.
There are 7 known substitutes for 5950-01-122-7266: 2010-00-415-7839, 6625-01-083-5979, 5962-01-123-4781 and 4 more. Verify interchangeability with system specifications before substitution.
Key specifications for 986260-1B: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Winding Quantity: 2 SINGLE COMPONENT; Winding Operating Current: 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT SECOND WINDING. 22 total characteristics are documented in the Federal Logistics Information System.