Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 2 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 1.830 INCHES NOMINAL IN
  • Body Height: 1.915 INCHES NOMINAL IN
  • Maximum Transformer Power Rating: 12.0 DECIBELS SINGLE COMPONENT
Identification
  • NSN: 5950-01-121-9018
  • NIIN: 011219018
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-121-9018, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-121-9018
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity2 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodUNTHREADED HOLE(S) SINGLE GROUP
Body Width1.830 INCHES NOMINAL IN
Body Height1.915 INCHES NOMINAL IN
Maximum Transformer Power Rating12.0 DECIBELS SINGLE COMPONENT
Mounting Hole Diameter0.320 INCHES NOMINAL SINGLE GROUP IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Distance Between Mounting Facility Centers2.810 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Body Length1.975 INCHES NOMINAL IN
Winding Operating Current28.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating140.0 HERTZ NOMINAL SINGLE COMPONENT
Winding Operating Voltage100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage30.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Terminal Type and Quantity6 WIRE HOOK
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
120-0852-00 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-121-9018?

NSN 5950-01-121-9018 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-121-9018?

Key specifications for 5950-01-121-9018: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT; Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP. 17 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-121-9018 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.