PartsTable TECHNICAL DATA SHEET
NSN 5950-01-118-5785Government record, cited

Transformer, Power5950-01-118-5785

NSN 5950-01-118-5785 · NIIN 011185785 · Part number 905867-0001
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp · FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 06481
Government record, cited
NSN 5950-01-118-5785 — this item is cataloged by the U.S. Government under National Stock Number 5950-01-118-5785. Manufacturer of record part number: 905867-0001.
Also searched as  5950-01-118-5785 · 5950011185785 · NIIN 011185785 · 01-118-5785 · FSC 5950 Coils and Transformers · CAGE 06481 · 905867-0001 · 905867-1 · 13089 · 03799
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: FULLY INCLOSED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 3.170 INCHES MINIMUM AND 3.190 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 13.8 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: UNTHREADED HOLE(S) SINGLE GROUP
  • Body Width: 1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM IN
Identification
  • NSN: 5950-01-118-5785
  • NIIN: 011185785
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 905867-0001
  • Manufacturer: Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-118-5785, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp. Government technical data includes 19 specifications, cited from the U.S. Government catalog. The record lists 4 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-118-5785
Primary Part Number905867-0001
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
ManufacturerNorthrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeFULLY INCLOSED
Center to Center Distance Between Mounting Facilities Parallel to Length3.170 INCHES MINIMUM AND 3.190 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating13.8 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodUNTHREADED HOLE(S) SINGLE GROUP
Body Width1.230 INCHES MINIMUM AND 1.270 INCHES MAXIMUM IN
Mounting Hole Diameter0.143 INCHES MINIMUM AND 0.149 INCHES MAXIMUM SINGLE GROUP IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Winding Shielding MethodINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
Maximum Operating Temp130.0 CELSIUS DEGC
Winding Operating Current529.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width0.920 INCHES MINIMUM AND 0.940 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Test Data Document06481-905867 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Terminal Type and Quantity7 TURRET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
6150-01-564-108213089 POSSIBLE MATCH
CABLE ASSEMBLY,SPECIAL PURPOSE,E
Possible match (shared part number)Carlisle & Finch Co
Cross-Reference Index
Part NumberManufacturer
905867-0001 PRIMARY Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA)
905867-1 PRIMARY Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA)
13089 Magnespec Inc (USA)
03799 Magnetika Inc (USA)
Related Parts
6150-01-564-1082POSSIBLE MATCH
CABLE ASSEMBLY,SPECIAL PURPOSE,E
13089

Frequently Asked Questions

What is NSN 5950-01-118-5785?

NSN 5950-01-118-5785 is a Transformer,power, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp, classified under FSC 5950, Coils and Transformers. Status: active.

What part numbers are listed for NSN 5950-01-118-5785?

NSN 5950-01-118-5785 has 4 manufacturer part numbers on file: 905867-0001 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp), 905867-1 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp), 13089 (Magnespec Inc), 03799 (Magnetika Inc).

What NSN replaces 5950-01-118-5785?

1 possible match (shared part number, not a government interchangeability claim): 6150-01-564-1082. Verify interchangeability with system specifications before substitution.

What are the specifications of 905867-0001?

Key specifications for 905867-0001: Overall Height: 1.050 INCHES MINIMUM AND 1.090 INCHES MAXIMUM IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 3.170 INCHES MINIMUM AND 3.190 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-118-5785 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.