PartsTable TECHNICAL DATA SHEET
NSN 5950-01-104-5001Government record, cited

Transformer, Power5950-01-104-5001

NSN 5950-01-104-5001 · NIIN 011045001
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-104-5001 · 5950011045001 · NIIN 011045001 · 01-104-5001 · FSC 5950 Coils and Transformers · 2532369T0 · Q8010904-1
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: OPEN
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 6.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Winding Power Rating: 1.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: SLOT SINGLE GROUP
  • Body Width: 6.750 INCHES NOMINAL IN
Identification
  • NSN: 5950-01-104-5001
  • NIIN: 011045001
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-104-5001, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-104-5001
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeOPEN
Center to Center Distance Between Mounting Facilities Parallel to Length6.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Power Rating1.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodSLOT SINGLE GROUP
Body Width6.750 INCHES NOMINAL IN
Body Height6.250 INCHES NOMINAL IN
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Body Length7.125 INCHES NOMINAL IN
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Winding Operating Voltage450.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Winding Operating Voltage86.00 AC VOLTS NOMINAL AND 90.00 AC VOLTS NOMINAL AND 94.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Terminal Type and Quantity6 WIRE LEAD
Reference Number Differentiating CharacteristicsAS DIFFERENTIATED BY SPECIAL FEATURES
Mounting Slot Width0.438 INCHES NOMINAL SINGLE GROUP IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
2532369T0 3/9 Design control — primary reference
Hevi Duty Electric Sola Basic Industries Inc Div a Unit of General Signal Corp
Q8010904-1 5/9 Secondary reference
Hevi Duty Electric Sola Basic Industries Inc Div a Unit of General Signal Corp
No interchangeability data on file.
Other items in FSC 5950 — Coils and Transformers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5950-00-000-0146
TRANSFORMER,POWER
5950-00-001-1372
COIL,RADIO FREQUENCY
5950-00-001-1386
COVER,ELECTRICAL TRANSFORMER
5950-00-001-1410
5950-00-001-1410 · Item name not on file
5950-00-001-1411
5950-00-001-1411 · Item name not on file
5950-00-001-1412
5950-00-001-1412 · Item name not on file
5950-00-001-1413
5950-00-001-1413 · Item name not on file
5950-00-001-1414
5950-00-001-1414 · Item name not on file

Frequently Asked Questions

What is NSN 5950-01-104-5001?

NSN 5950-01-104-5001 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What are the specifications of 5950-01-104-5001?

Key specifications for 5950-01-104-5001: Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: OPEN; Center to Center Distance Between Mounting Facilities Parallel to Length: 6.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Winding Power Rating: 1.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY. 17 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-104-5001 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com