PartsTable TECHNICAL DATA SHEET
NSN 5950-01-104-1902Government record, cited

Transformer, Power5950-01-104-1902

NSN 5950-01-104-1902 · NIIN 011041902
FSC 5950 — Coils and Transformers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5950-01-104-1902 · 5950011041902 · NIIN 011041902 · 01-104-1902 · FSC 5950 Coils and Transformers · MIL-T-27/50 · MIL-PRF-27/50 · MIL-PRF-27/49 · M27/50-02A
Nearby stock numbers  ·
Features
  • Transformer,power — FSC 5950
  • Mounting Facility Quantity: 2 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Body Outside Diameter: 0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM IN
  • Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
  • Mounting Method: THREADED STUD(S) SINGLE GROUP
  • Maximum Transformer Power Rating: 3.0 VOLT-AMPERE SINGLE COMPONENT
  • Winding Function and Quantity: 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Identification
  • NSN: 5950-01-104-1902
  • NIIN: 011041902
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Transformer,power, cataloged under National Stock Number 5950-01-104-1902, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 12 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-104-1902
Item NameTransformer,power
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity2 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Body Outside Diameter0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM IN
Input-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
Mounting MethodTHREADED STUD(S) SINGLE GROUP
Maximum Transformer Power Rating3.0 VOLT-AMPERE SINGLE COMPONENT
Winding Function and Quantity1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
Distance Between Mounting Facility Centers0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Nominal Thread Size0.112 INCHES SINGLE GROUP IN
Specification/standard Data81349-MIL-T-27/50 GOVERNMENT SPECIFICATION
Maximum Operating Temp130.0 CELSIUS DEGC
Body Length0.563 INCHES MINIMUM AND 0.625 INCHES MAXIMUM IN
Winding Operating Current476.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Reliability IndicatorNOT ESTABLISHED
Frequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
Test Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Winding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
Winding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
Terminal Type and Quantity5 FEED THRU
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Hazardous Locations/environmental ProtectionVIBRATION RESISTANT
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 12
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5950-01-104-4416 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-104-4420 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-109-7160 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-137-0214 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-159-3859 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-184-5299 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-184-5300 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-229-2572 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-229-2585 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
5950-01-265-1623 POSSIBLE MATCH
TRANSFORMER,POWER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-T-27/50 5/9 Secondary reference
U.S. Government activity
MIL-PRF-27/50 4/1 Identification reference
U.S. Government activity
MIL-PRF-27/49 5/9 Secondary reference
U.S. Government activity
M27/50-02A 2/2 Government specification standardization
U.S. Government activity
Related Parts
5950-01-104-4416POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-104-4420POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-109-7160POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-137-0214POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-159-3859POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-184-5299POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-184-5300POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-229-2572POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-229-2585POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-265-1623POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-265-1637POSSIBLE MATCH
TRANSFORMER,POWER
5950-01-390-6629POSSIBLE MATCH
TRANSFORMER,POWER

Frequently Asked Questions

What is NSN 5950-01-104-1902?

NSN 5950-01-104-1902 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-104-1902?

12 possible matches (shared part number, not a government interchangeability claim): 5950-01-104-4416, 5950-01-104-4420, 5950-01-109-7160. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-104-1902?

Key specifications for 5950-01-104-1902: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Body Outside Diameter: 0.969 INCHES MINIMUM AND 1.031 INCHES MAXIMUM IN; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-104-1902 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com