Features
  • Reactor — FSC 5950
  • Mounting Facility Quantity: 4 SINGLE GROUP
  • Inclosure Type: HERMETICALLY SEALED
  • Center to Center Distance Between Mounting Facilities Parallel to Length: 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
  • Mounting Method: THREADED HOLE(S) SINGLE GROUP
  • Inductance Rating: 65.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY
  • Winding Conductor Size: 0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY IN
  • Nominal Thread Size: 0.112 INCHES SINGLE GROUP IN
Identification
  • NSN: 5950-01-100-7894
  • NIIN: 011007894
  • FSC: 5950 — Coils and Transformers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Reactor, cataloged under National Stock Number 5950-01-100-7894, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 18 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5950-01-100-7894
Item NameReactor
FSC / FSG5950 / 59 — Coils and Transformers
StatusACTIVE
Mounting Facility Quantity4 SINGLE GROUP
Inclosure TypeHERMETICALLY SEALED
Center to Center Distance Between Mounting Facilities Parallel to Length1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Mounting MethodTHREADED HOLE(S) SINGLE GROUP
Inductance Rating65.00 MILLIHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY
Winding Conductor Size0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY IN
Nominal Thread Size0.112 INCHES SINGLE GROUP IN
Maximum Operating Temp105.0 CELSIUS DEGC
Winding Operating Current0.2 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
Rating MethodELECTRICAL SINGLE COMPONENT SINGLE WINDING
DC Resistance Rating in Ohms1.500 SINGLE COMPONENT SINGLE PRIMARY
Reliability IndicatorNOT ESTABLISHED
Winding Quantity1 SINGLE COMPONENT
Frequency Rating60.0 HERTZ NOMINAL SINGLE COMPONENT
Center to Center Distance Between Mounting Facilities Parallel to Width1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN
Terminal Type and Quantity2 WIRE HOOK
Inductance TypeFIXED
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC) SINGLE GROUP
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5330-01-374-9802790545-003 POSSIBLE MATCH
PARTS KIT,SEAL REPLACEMENT,MECHA
Possible match (shared part number)Pacific Consolidated Industries Llc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
7905450-03 3/2 Design control — primary reference
U.S. Government activity
67076970 5/2 Secondary reference
U.S. Government activity
Related Parts
5330-01-374-9802POSSIBLE MATCH
PARTS KIT,SEAL REPLACEMENT,MECHA
790545-003

Frequently Asked Questions

What is NSN 5950-01-100-7894?

NSN 5950-01-100-7894 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.

What NSN replaces 5950-01-100-7894?

1 possible match (shared part number, not a government interchangeability claim): 5330-01-374-9802. Verify interchangeability with system specifications before substitution.

What are the specifications of 5950-01-100-7894?

Key specifications for 5950-01-100-7894: Overall Height: 1.812 INCHES MAXIMUM IN; Mounting Facility Quantity: 4 SINGLE GROUP; Inclosure Type: HERMETICALLY SEALED; Center to Center Distance Between Mounting Facilities Parallel to Length: 1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN. 18 specifications are documented in the U.S. Government catalog.

Is NSN 5950-01-100-7894 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com