The Transformer,power, cataloged under National Stock Number 5950-01-080-8150, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 12 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-080-8150 |
| Item Name | Transformer,power |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 2 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| Mounting Method | FLANGE AND THREADED HOLE(S) SINGLE GROUP |
| Maximum Transformer Power Rating | 20.0 KILOVOLT-AMPERE SINGLE COMPONENT |
| Winding Function and Quantity | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| Winding Shielding Method | INTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT |
| Distance Between Mounting Facility Centers | 0.780 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Nominal Thread Size | 0.112 INCHES SINGLE GROUP IN |
| Reliability Indicator | NOT ESTABLISHED |
| Terminal Type and Quantity | 6 TAB, SOLDER LUG AND 1 WIRE LEAD W/TUBE CAP |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| FS3451 | 5/9 Secondary reference Conrac Systems Inc |
| FS30062S-A | 5/9 Secondary reference Conrac Systems Inc |
| 782083 | 3/9 Design control — primary reference Conrac Systems Inc |
| 782055 | 5/9 Secondary reference Conrac Systems Inc |
NSN 5950-01-080-8150 is a Transformer,power, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-080-8150: Overall Height: 2.300 INCHES NOMINAL IN; Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Input-Output Phase Relationship: SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT. 12 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.