The Reactor, cataloged under National Stock Number 5950-01-074-6938, is classified within Federal Supply Class 5950 (Coils and Transformers) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5950-01-074-6938 |
| Item Name | Reactor |
| FSC / FSG | 5950 / 59 — Coils and Transformers |
| Status | ACTIVE |
| Mounting Facility Quantity | 2 SINGLE GROUP |
| Inclosure Type | FULLY INCLOSED |
| Center to Center Distance Between Mounting Facilities Parallel to Length | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN |
| Mounting Method | UNTHREADED HOLE(S) AND FLANGE SINGLE GROUP |
| Inductance Rating | 105.00 HENRY NOMINAL SINGLE COMPONENT ALL WINDING |
| Body Width | 1.186 INCHES NOMINAL IN |
| Body Height | 1.500 INCHES NOMINAL IN |
| Mounting Hole Diameter | 0.140 INCHES NOMINAL SINGLE GROUP IN |
| Body Length | 1.920 INCHES NOMINAL IN |
| DC Resistance Rating in Ohms | 0.053 SINGLE COMPONENT ALL WINDING |
| Winding Quantity | 3 SINGLE COMPONENT |
| Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| Terminal Type and Quantity | 6 TURRET |
| Inductance Type | FIXED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 739660-1 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5950-01-074-6938 is a Reactor, classified under FSC 5950, Coils and Transformers. Status: active.
Key specifications for 5950-01-074-6938: Mounting Facility Quantity: 2 SINGLE GROUP; Inclosure Type: FULLY INCLOSED; Center to Center Distance Between Mounting Facilities Parallel to Length: 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP IN; Mounting Method: UNTHREADED HOLE(S) AND FLANGE SINGLE GROUP. 14 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.